Array ACFM probes for challenging subsea applications.
Scanned Array 542 Probe
General Specifications
Compatible instruments
- U41R
- MagCrawler
- NodeScanner
Operational depth
1 km (0.5 mi)
Applications
Flat surfaces
Scan width
50 mm (1.97 in)
Number of rows/channels
8 / 32
Fields/Sensors
x / y
Scanned Array 543 Probe
General Specifications
Compatible instruments
- U41R
- MagCrawler
- NodeScanner
Operational depth
1 km (0.5 mi)
Applications
Flat surfaces
Scan width
- 26 mm (1 in) bottom
- 10 mm (0.4 in) each side
Number of rows/channels
7 / 28
Fields/Sensors
x / y
Scanned Array 493 Probe
General Specifications
Compatible instruments
- U41R
- MagCrawler
- NodeScanner
Operational depth
1 km (0.5 mi)
Applications
Tight access
Scan width
- 8 mm (0.3 in) bottom
- 35 mm (1.4 in) each side
Number of rows/channels
15 / 30
Fields/Sensors
x
Pick and Place Array 497 Probe
General Specifications
Compatible instruments
- U41R
- MagCrawler
- NodeScanner
Operational depth
1 km (0.5 mi)
Applications
Low-dexterity deployment
Scan width
- 80 mm long (3.2 in)
- 20 mm wide (0.8 in)
Number of rows/channels
2 / 32
Fields/Sensors
x
Low-Profile Mini 549 Probe
General Specifications
Compatible instruments
- U41R
- MagCrawler
- NodeScanner
Operational depth
1 km (0.5 mi)
Applications
Low-overhang area
Scan width
40 mm long (1.6 in)
Number of rows/channels
6 / 24
Fields/Sensors
x / y